BOOK 2, CHAPTER 1: Hydraulic Accumulators (part 1)
The accumulator and actuators fill from the pump until system pressure reaches 2000 psi. At 2000 psi, the pump unloads through a solenoid operated relief valve at approximately 50 psi. The main advantage of the circuit in Figure 1-15 is that pressure drop is adjustable by more or less than the fixed 15% allowed by the unloading valve in Figure ...